SOMInstitute Solar Operations Maturity Institute

The model

Seven areas.
Six levels.
One spine.

In the maturity model of the Solar Operations Maturity Institute (SOM Institute), every area is rated on the same 0–5 spine, so levels are comparable across areas. What changes from one area to the next is what each level looks like in practice. This page sets out every level of every area.

The spine

From blind to optimised and quantified.

The six levels every area climbs. Below, each area describes its levels in its own concrete terms; the spine is what lets a level in one area be compared with the same level in another.

  1. Level 0: Blind
  2. Level 1: Manual
  3. Level 2: Reactive tooling
  4. Level 3: Systematic
  5. Level 4: Automated & integrated
  6. Level 5: Optimised & quantified

How a level is read

An area’s level
The average of its questions.
Not applicable
An area marked not applicable is not rated, rather than scored zero.
Against peers
Comparison with peers is made area by area.
The gap
The level you want to reach minus where you are today.
Priority
How important the area is to you, multiplied by the gap.
Weighting
All seven areas carry equal weight.

Where the model comes from

Area 1 of 7

Monitoring

How quickly a fault at a site is identified and acted on.

All seven areas

  1. Level 0, Blind

    No monitoring

    We find out a site is down when someone else tells us.

  2. Level 1, Manual

    Portal-by-portal

    We log in to each vendor portal manually, when prompted.

  3. Level 2, Reactive tooling

    Vendor alerts

    Per-brand portal alerts are on; someone scans them most days.

  4. Level 3, Systematic

    One view

    A consolidated cross-brand view; offline sites are caught within hours.

  5. Level 4, Automated & integrated

    Alerting with ownership

    Near-real-time alerts routed to a person with an escalation path and response expectations.

  6. Level 5, Optimised & quantified

    Measured & prioritised

    Alert noise is managed, detection/response times are measured, and the highest-impact sites are watched hardest.

Area 2 of 7

Performance

How each site’s output is measured against expectation, and how well shortfalls are understood.

All seven areas

  1. Level 0, Blind

    Not tracked

    Production is whatever it is.

  2. Level 1, Manual

    Eyeballed

    Monthly glance at kWh vs a gut feel or last month.

  3. Level 2, Reactive tooling

    Vs a static estimate

    Compared against the design estimate or yield guarantee only.

  4. Level 3, Systematic

    Weather-adjusted

    Expected production per site reflects the weather that actually happened; shortfalls are flagged.

  5. Level 4, Automated & integrated

    Causes attributed

    Underperformance is detected fleet-wide and traced to its root cause (soiling, shading, string faults, diode failures).

  6. Level 5, Optimised & quantified

    Every lost kWh explained and costed

    Losses are attributed, valued in Rands, benchmarked, and drive a planned remediation list.

Area 3 of 7

Data Quality

How far the underlying data can be relied on.

All seven areas

  1. Level 0, Blind

    Unknown

    Gaps and errors in site data go unnoticed.

  2. Level 1, Manual

    Found by accident

    Data problems surface when a report looks wrong.

  3. Level 2, Reactive tooling

    Spot checks

    Occasional manual review of data completeness.

  4. Level 3, Systematic

    Gap detection

    Missing data is detected and backfilled systematically.

  5. Level 4, Automated & integrated

    Cross-validated

    Independent sources (meter vs inverter) are reconciled routinely.

  6. Level 5, Optimised & quantified

    Quantified confidence

    Data completeness/accuracy is measured per site, and every downstream number carries that confidence.

Area 4 of 7

Data Analysis

How far analysis goes below site totals — string, temperature, voltage, load.

All seven areas

  1. Level 0, Blind

    Raw data only

    Nobody looks below site-level totals.

  2. Level 1, Manual

    Occasional exports

    Data pulled to Excel now and then, when there’s a problem.

  3. Level 2, Reactive tooling

    Portal charting

    Per-site charts in vendor portals, on demand.

  4. Level 3, Systematic

    String & temperature analysis

    String-level and AC/DC/BMS temperature analysis is done when investigating.

  5. Level 4, Automated & integrated

    Automated anomaly analysis

    String, temperature and alert-pattern anomalies are surfaced automatically per site.

  6. Level 5, Optimised & quantified

    Continuous fleet analytics

    The whole fleet is analysed continuously; faults are found without anyone asking.

Area 5 of 7

Optimisation

How actively the installed system is adjusted to improve its financial return.

All seven areas

  1. Level 0, Blind

    Commissioning settings

    Inverters run whatever was set on day one.

  2. Level 1, Manual

    Occasional tweaks

    Settings changed manually when someone thinks of it.

  3. Level 2, Reactive tooling

    Seasonal reviews

    Periodic reviews of setpoints and tariff settings.

  4. Level 3, Systematic

    Per-site optimisation

    Charge/discharge tuned to each site’s tariff windows and load shape.

  5. Level 4, Automated & integrated

    Simulation-backed

    Upgrades are chosen from simulations with predicted ROI.

  6. Level 5, Optimised & quantified

    Continuous & verified

    Optimisation runs continuously and the realised savings are measured and reported.

Area 6 of 7

Finance

How generation is translated into figures finance teams and funders accept.

All seven areas

  1. Level 0, Blind

    No financial view

    Energy data never becomes money.

  2. Level 1, Manual

    Rules of thumb

    Savings estimated with a generic c/kWh figure.

  3. Level 2, Reactive tooling

    Estimated savings

    Calculated, but on approximate or outdated tariffs.

  4. Level 3, Systematic

    Tariff-accurate

    Savings and utility-bill reconciliations use each site’s actual tariff.

  5. Level 4, Automated & integrated

    Asset-level finance

    IRR and ROI per asset, with billing and reconciliation systemised.

  6. Level 5, Optimised & quantified

    Auditable

    Financial reporting stands up to owners, auditors and funders.

Area 7 of 7

Reporting

What reaches clients, boards and colleagues, and how much is assembled by hand.

All seven areas

  1. Level 0, Blind

    None

    No regular reporting exists.

  2. Level 1, Manual

    On request

    Screenshots and ad-hoc emails when someone asks.

  3. Level 2, Reactive tooling

    Manual monthly

    Someone copies numbers into a template every month.

  4. Level 3, Systematic

    Automated & standard

    Standardised reports generate and send themselves.

  5. Level 4, Automated & integrated

    Role-tailored

    Distinct O&M / finance / customer reports, plus a customer-facing portal.

  6. Level 5, Optimised & quantified

    Insight-driven

    Reporting is exception-led; it tells each reader what needs their attention, and customers self-serve the rest.

Index

Read across a level.

The same six levels, read across all seven areas: what each level is called in each area.

Level 0, Blind
  • Monitoring: No monitoring
  • Performance: Not tracked
  • Data Quality: Unknown
  • Data Analysis: Raw data only
  • Optimisation: Commissioning settings
  • Finance: No financial view
  • Reporting: None
Level 1, Manual
  • Monitoring: Portal-by-portal
  • Performance: Eyeballed
  • Data Quality: Found by accident
  • Data Analysis: Occasional exports
  • Optimisation: Occasional tweaks
  • Finance: Rules of thumb
  • Reporting: On request
Level 2, Reactive tooling
  • Monitoring: Vendor alerts
  • Performance: Vs a static estimate
  • Data Quality: Spot checks
  • Data Analysis: Portal charting
  • Optimisation: Seasonal reviews
  • Finance: Estimated savings
  • Reporting: Manual monthly
Level 3, Systematic
  • Monitoring: One view
  • Performance: Weather-adjusted
  • Data Quality: Gap detection
  • Data Analysis: String & temperature analysis
  • Optimisation: Per-site optimisation
  • Finance: Tariff-accurate
  • Reporting: Automated & standard
Level 4, Automated & integrated
  • Monitoring: Alerting with ownership
  • Performance: Causes attributed
  • Data Quality: Cross-validated
  • Data Analysis: Automated anomaly analysis
  • Optimisation: Simulation-backed
  • Finance: Asset-level finance
  • Reporting: Role-tailored
Level 5, Optimised & quantified
  • Monitoring: Measured & prioritised
  • Performance: Every lost kWh explained and costed
  • Data Quality: Quantified confidence
  • Data Analysis: Continuous fleet analytics
  • Optimisation: Continuous & verified
  • Finance: Auditable
  • Reporting: Insight-driven

The Solar O&M Maturity Survey

Place your operation on the ladder.

Area by area, the survey asks where you are today and where you want to be. Under ten minutes; results are emailed within about two weeks of the survey closing.

Take the survey